2.2.40.1. Terminology

A door lock supports at least 2 modes: secured (it cannot be opened with handles) and unsecured (it can be opened with handles). It may support more modes where the node is for example secured only for the inside handles.

A door lock may have several components such as a latch, a bolt and handles.

A latch, which can also be called a latch bolt or spring bolt, usually locks the door automatically when closing it. The latch bolt is disengaged (retracted) typically when the user turns the door handle, which via the lockset’s mechanism, manually retracts the latch bolt, allowing the door to open.

Handles allow to retract the door’s latch.

A bolt, also named dead bolt and hook bolt, allows to secure the door. When the bolt is out or extended, the door lock is usually secured (locked) but there are locks that are unlocked even then the bolt is out which will withdraw the bolt when user turns the door handle (which also retract the latch). The position of the bolt is not directly related to the Door Lock Mode.

A supporting door lock runs in constant operation by default. In constant operation, the door lock stays in the same mode until receiving a new command or being locally actuated. A door lock may support timed operation. Timed operation has its own subset of modes, which after being activated will automatically return to the secured mode after the configured Lock Timeout.

An auto-relock functionality can be supported for returning automatically to secured mode some given time after any operation mode change, including constant operation or changes initiated physically by a user (unlocking with key, thumb turn, etc). Auto-relock should not have any effect when the lock runs in Timed Operation

A door lock node may have a twist assist mechanism. When a user starts rotating a key or the thumb turn to unlock the door, a motor starts rotating to help the user completing the movement. It can be helpful for disabled users.

A node may support a hold and release functionality for spring latches. This is useful for locks having a handle that cannot retract the door spring latch on one side. This functionality defines how long the spring latch must be retracted after the door mode has been changed to unsecured.

A block-to-block functionality can be activated for locks having separate lock block on each side of the door and cannot sense local changes on one side. Enabling the block-to-block feature will make the door lock try to execute a lock or unlock command on both sides regardless of the last known lock mode (representing the side that can be sensed). When this feature is disabled, the lock will ignore a command indicating a mode if it is identical to the last known lock mode.

2.2.40.2. Compatibility considerations

\requirement{CC:0062.04.00.21.001}{4}

The Door Lock Command Class, version 4 is backwards compatible with the Door Lock Command Class, version 3. Fields and commands not mentioned in this version MUST remain unchanged from the Door Lock Command Class, version 3.

Commands for advertising node capabilities are introduced in this version:

  • Door Lock Capabilities Get Command

  • Door Lock Capabilities Report Command

These commands are extended in order to provide the auto-relock, twist assist and block-to-block functionalities.

  • Door Lock Configuration Set Command

  • Door Lock Configuration Report Command

2.2.40.3. Door Lock Operation Set Command

This command is used to set the mode of a supporting door lock node.

Table 2.204 Door Lock Operation Set Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_OPERATION_SET (0x01)

Door Lock Mode

Door Lock Mode (8 bits)

\requirement{CC:0062.04.01.11.001}{0}

This field is used to specify the operation mode that the supporting node MUST assume. This field MUST be encoded according to Table 2.205.

Table 2.205 Door Lock Operation Set::Mode encoding

Value

Mode Description

Operation Type

Version

0x00

Door Unsecured

Constant

1

0x01

Door Unsecured with timeout

Timed

1

0x10

Door Unsecured for inside Door Handles

Constant

1

0x11

Door Unsecured for inside Door Handles with timeout

Timed

1

0x20

Door Unsecured for outside Door Handles

Constant

1

0x21

Door Unsecured for outside Door Handles with timeout

Timed

1

0xFF

Door Secured

Constant

1

All other values are reserved and MUST NOT be used by a sending node. Reserved values MUST be ignored by a receiving node.

\requirement{CC:0062.04.01.51.001}{0}

A controlling node MUST NOT specify modes using timeout-based fall back if the Operation Type of the supporting device is set to Constant operation (set by Door Lock Configuration Set).

\requirement{CC:0062.04.01.11.002}{0}

A supporting node MUST ignore modes using timeout-based fall back if Operation Type is set to Constant operation.

\requirement{CC:0062.04.01.11.003}{0}

A supporting node MUST apply the constant modes without any timeout even if it is configured to run in Timed Operation.

\requirement{CC:0062.04.01.11.004}{0}

A supporting node MUST ignore the command if the value specified in this field is not advertised as supported in the Door Lock Capabilities Report Command.

\requirement{CC:0062.04.01.11.005}{0}

A supporting node MUST support the door lock mode values 0x00 and 0xFF.

2.2.40.4. Door Lock Operation Get Command

This command is used to request the mode of a supporting door lock node.

\requirement{CC:0062.04.02.11.001}{0}

The Door Lock Operation Report Command MUST be returned in response to this command.

\requirement{CC:0062.04.02.51.001}{0}

This command MUST NOT be issued via multicast addressing.

\requirement{CC:0062.04.02.11.002}{0}

A receiving node MUST NOT return a response if this command is received via multicast addressing. The Z-Wave Multicast frame, the broadcast NodeID and the Multi Channel multi-End Point destination are all considered multicast addressing methods.

Table 2.206 Door Lock Operation Get Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_OPERATION_GET (0x02)

2.2.40.5. Door Lock Operation Report Command

This command is used to advertise the mode of a supporting door lock node.

Table 2.207 Door Lock Operation Report Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_OPERATION_REPORT (0x03)

Current Door Lock Mode

Outside Door Handles Mode

Inside Door Handles Mode

Door Condition

Remaining Lock Time Minutes

Remaining Lock Time Seconds

Target Door Lock Mode

Duration

Current Door Lock Mode (8 bits)

\requirement{CC:0062.04.03.11.001}{0}

This field MUST advertise the current door lock mode of the sending node. This field MUST be encoded according to Table 2.208.

Table 2.208 Door Lock Operation Report::Mode encoding

Value

Mode Description

Operation Type

Version

0x00

Door Unsecured

Constant (or timed)

1

0x01

Door Unsecured with timeout

Timed

1

0x10

Door Unsecured for inside Door Handles

Constant (or timed)

1

0x11

Door Unsecured for inside Door Handles with timeout

Timed

1

0x20

Door Unsecured for outside Door Handles

Constant (or timed)

1

0x21

Door Unsecured for outside Door Handles with timeout

Timed

1

0xFE

Door mode unknown (e.g. bolt not fully retracted)

N/A

2

0xFF

Door Secured

Constant (or timed)

1

All other values are reserved and MUST NOT be used by a sending node. Reserved values MUST be ignored by a receiving node.

\requirement{CC:0062.04.03.12.001}{0}

A sending node SHOULD set this field to 0xFE if sending this command while performing a transition between 2 modes.

Outside Door Handles Mode (4 bits)

This field is used to advertise the status of each individual outside door handle.

\requirement{CC:0062.04.03.11.002}{0}

This field MUST be treated as a bitmask field and MUST be encoded according to Table 2.209.

Table 2.209 Door Lock Operation Report::Door Handles Mode bitmask encoding

Bit 3

Bit 2

Bit 1

Bit 0

Handle 4

Handle 3

Handle 2

Handle 1

\requirement{CC:0062.04.03.11.003}{0}

The value 0 MUST indicate that the actual handle cannot open the door locally.

The value 1 MUST indicate that the actual handle can open the door locally.

Inside Door Handles Mode (4 bits)

This field is used to advertise the status of each individual inside door handle.

\requirement{CC:0062.04.03.11.004}{0}

This field MUST be treated as a bitmask field and MUST be encoded according to Table 2.209.

\requirement{CC:0062.04.03.11.005}{0}

The value 0 MUST indicate that the actual handle cannot open the door locally.

The value 1 MUST indicate that the actual handle can open the door locally.

Door Condition (8 bits)

This field is used to advertise the state of the door lock components.

\requirement{CC:0062.04.03.11.006}{0}

This field MUST be encoded according to Table 2.210.

Table 2.210 Door Lock Operation Report::Door Condition bitmask encoding

Value

Bit 7..3

Bit 2

Bit 1

Bit 0

bit set to ‘0’

Reserved

Latch Open (out, engaged, extended)

Bolt Locked (out, extended)

Door Open

bit set to ‘1’

Reserved

Latch Closed (in, disengaged, retracted)

Bolt Unlocked (in, retracted)

Door Closed

All other bits are reserved and MUST be set to zero by a sending node. Reserved bits MUST be ignored by a receiving node.

\requirement{CC:0062.04.03.11.007}{0}

If a door component is not advertised as supported in the Door Lock Capabilities Report Command, the corresponding bit MUST be set to 0 and MUST be ignored by a controlling node.

Remaining Lock Time Minutes (8 bits)

This field is used to advertise the remaining time before the door lock mode will automatically be changed to “secured” if operating in timed operation with a timed operation mode.

\requirement{CC:0062.04.03.11.008}{0}

This field MUST be encoded according to Table 2.211. The remaining time that the sending node will stay in the current mode MUST be determined by combining this field and the Remaining Lock Time Seconds field.

Table 2.211 Door Lock Operation Report::Remaining Lock Time Minutes encoding

Value

Description

0..253 (0x00..0xFD)

0..253 minutes (Operation Type and Current mode = Timed Operation)

254 (0xFE)

Undefined

All other values are reserved and MUST NOT be used by a sending node. Reserved values MUST be ignored by a receiving node.

\requirement{CC:0062.04.03.11.009}{0}

A node currently set in a constant operation type mode MUST set this field to 0xFE. However, if unsecured with the auto-relock functionality active, it MAY advertise the time remaining before auto-relock secures the lock again.

Remaining Lock Time Seconds (8 bits)

This field is used to advertise the remaining time before the door lock mode will automatically be changed to “secured” if operating in timed operation with a timed operation mode.

\requirement{CC:0062.04.03.11.00A}{0}

This field MUST be encoded according to Table 2.212. The remaining time that the sending node will stay in the current mode MUST be determined by combining this field and the Remaining Lock Time Minutes field.

Table 2.212 Door Lock Operation Report::Remaining Lock Time Seconds encoding

Value

Description

0..59 (0x00..0x3B)

0..59 seconds (Operation Type and mode= Timed Operation)

254 (0xFE)

Undefined

All other values are reserved and MUST NOT be used by a sending node. Reserved values MUST be ignored by a receiving node.

\requirement{CC:0062.04.03.11.00B}{0}

A node currently set in a constant operation type mode MUST set this field to 0xFE. However, if unsecured with the auto-relock functionality active, it MAY advertise the time remaining before auto-relock secures the lock again.

Target Door Lock Mode (8 bits)

This field is used to advertise the target mode of an ongoing transition or of the most recent transition.

\requirement{CC:0062.04.03.11.00C}{0}

This field MUST be encoded according to Table 2.208. This field MUST be set to the mode specified in the most-recent received Door Lock Operation Set Command.

\requirement{CC:0062.04.03.11.00D}{0}

If the node is going to change mode due to the auto-relock functionality or a timed operation, this field MUST NOT advertise the future mode and MUST be set to the same value as the Current Door Lock Mode field.

\requirement{CC:0062.04.03.11.00E}{0}

If no transition is ongoing, this field MUST be set to the same value as the Current Door Lock Mode field.

\requirement{CC:0062.04.03.11.00F}{0}

If the Current Door Lock Mode is set to 0xFE, this field MUST indicate the mode is it going to assume when the ongoing transition has been completed.

Duration (8 bits)

\requirement{CC:0062.04.03.12.002}{0}

This field SHOULD advertise the estimated remaining time before the mode indicated in the Target Door Lock Mode field is reached.

\requirement{CC:0062.04.03.11.010}{0}

This field MUST be set to 0 if the Target Door Lock Mode and Current Door Lock Mode fields are set to the same value.

\requirement{CC:0062.04.03.11.011}{0}

The encoding of this field MUST be according to Table 2.10.

2.2.40.6. Door Lock Configuration Set Command

This command is used to set the configuration of a supporting door lock node.

\requirement{CC:0062.04.04.11.001}{0}

A supporting node MUST be able to operate with the factory default configuration.

Table 2.213 Door Lock Configuration Set Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_CONFIGURATION_SET (0x04)

Operation Type

Outside Door Handles Enabled

Inside Door Handles Enabled

Lock Timeout Minutes

Lock Timeout Seconds

Auto-relock time 1 (MSB)

Auto-relock time 2 (LSB)

Hold and release time 1 (MSB)

Hold and release time 2 (LSB)

Reserved

BTB

TA

Operation Type (1 byte)

\requirement{CC:0062.04.04.11.002}{0}

This field is used to set the operation type at the supporting node. This field MUST be encoded according to Table 2.214.

Table 2.214 Door Lock Configuration Set::Operation Type encoding

Value

Description

Version

0x01

Constant operation

1

0x02

Timed operation

1

All other values are reserved and MUST NOT be used by a sending node. Reserved values MUST be ignored by a receiving node.

\requirement{CC:0062.04.04.11.003}{4}

If this field is set to timed operation (0x02), the Lock Timeout Minutes and Lock Timeout Seconds fields MUST be set to values different than 0xFE.

\requirement{CC:0062.04.04.11.004}{0}

A supporting node MUST ignore this field if it is set to an operation type that is not advertised as supported in the Door Lock Capabilities Report Command.

Outside Door Handles Enabled (4 bits)

\requirement{CC:0062.04.04.11.005}{0}

This field is used to enable or disable each individual outside door handle at the supporting node. This field MUST be treated as a bitmask and MUST be encoded according to Table 2.209.

\requirement{CC:0062.04.04.11.006}{0}

The value 0 MUST indicate that the actual handle cannot open the door locally.

The value 1 MUST indicate that the actual handle can open the door locally.

\requirement{CC:0062.04.04.11.007}{0}

A supporting node MUST ignore an outside door handle mode value if it advertises no support for the corresponding handle in the Door Lock Capabilities Report Command.

Inside Door Handles Enabled (4 bits)

\requirement{CC:0062.04.04.11.008}{0}

This field is used to enable or disable each individual inside door handle at the supporting node. This field MUST be treated as a bitmask and MUST be encoded according to Table 2.209.

\requirement{CC:0062.04.04.11.009}{0}

The value 0 MUST indicate that the actual handle cannot open the door locally.

The value 1 MUST indicate that the actual handle can open the door locally.

\requirement{CC:0062.04.04.11.00A}{0}

A supporting node MUST ignore an inside door handle mode value if it advertises no support for the corresponding handle in the Door Lock Capabilities Report Command.

Lock Timeout Minutes (8 bits)

This field is used to specify the time that the supporting node must wait before returning to the secured mode when receiving timed operation modes in a Door Lock Operation Set Command.

\requirement{CC:0062.04.04.11.00B}{0}

Values in the range 0x00..0xFD MUST indicate the actual number of minutes.

The value 0xFE MUST indicate that this field is undefined.

\requirement{CC:0062.04.04.11.00C}{0}

This field MUST be set to 0xFE if the Operation Type field is set to 0x01 (constant operation)

This field MUST be in the range 0x00..0xFD if the Operation Type field is set to 0x02 (timed operation)

\requirement{CC:0062.04.04.11.00D}{0}

The time to stay unlocked MUST be determined by combining this field and the Lock Timeout Seconds fields.

\requirement{CC:0062.04.04.11.00E}{0}

A supporting node MUST ignore this field if it is set to the timed operation type is not advertised as supported in the Door Lock Capabilities Report Command.

Lock Timeout Seconds (8 bits)

This field is used to specify the time that the supporting node must wait before returning to the secured mode when receiving timed operation modes in a Door Lock Operation Set Command.

\requirement{CC:0062.04.04.11.00F}{0}

Values in the range 0x00..0x3B MUST indicate the actual number of seconds.

The value 0xFE MUST indicate that this field is undefined.

\requirement{CC:0062.04.04.11.010}{0}

This field MUST be set to 0xFE if the Operation Type field is set to 0x01 (constant operation)

This field MUST be in the range 0x00..0x3B if the Operation Type field is set to 0x02 (timed operation)

\requirement{CC:0062.04.04.11.011}{0}

The time to stay unlocked MUST be determined by combining this field and the Lock Timeout Minutes field.

\requirement{CC:0062.04.04.11.012}{0}

A supporting node MUST ignore this field if it is set to the timed operation type is not advertised as supported in the Door Lock Capabilities Report Command.

Auto-relock time (16 bits)

This field is used to specify the time setting in seconds for auto-relock functionality.

\requirement{CC:0062.04.04.11.013}{0}

This field MUST be ignored by a node advertising no support for the auto-relock functionality in the Door Lock Capabilities Report Command.

\requirement{CC:0062.04.04.11.014}{0}

The value 0 MUST indicate that the auto-relock functionality is disabled and the door lock MUST NOT return to secured mode automatically. (unless using Timed Operation)

\requirement{CC:0062.04.04.11.015}{0}

Values in the range 1..65535 MUST indicate that the auto-relock functionality is enabled and the supporting node MUST return to secured mode after the time in seconds indicated by this field.

Hold and release time (16 bits)

This field is used to specify the time setting in seconds for letting the latch retracted after the supporting node’s mode has been changed to unsecured.

\requirement{CC:0062.04.04.11.016}{0}

This field MUST be ignored by a node advertising no support for the hold and release functionality in the Door Lock Capabilities Report Command.

\requirement{CC:0062.04.04.11.017}{0}

The value 0 MUST indicate that the hold and release functionality is disabled and the supporting node MUST NOT keep the latch retracted when the door lock mode becomes unsecured.

\requirement{CC:0062.04.04.11.018}{0}

Values in the range 1..65535 MUST indicate that the hold and release functionality is enabled and the door lock latch MUST keep open according to the time in seconds indicated by this field.

TA (Twist assist) (1 bit)

\requirement{CC:0062.04.04.11.019}{0}

This field MUST indicate if the twist assist functionality is enabled.

\requirement{CC:0062.04.04.11.01A}{0}

This field MUST be ignored by a node advertising no support for the twist assist functionality in the Door Lock Capabilities Report Command.

\requirement{CC:0062.04.04.11.01B}{0}

The value 0 MUST indicate that the twist assist functionality MUST be disabled at the supporting node.

The value 1 MUST indicate that the twist assist functionality MUST be enabled at the supporting node.

BTB (Block-to-block) (1 bit)

This field is used to indicate if the block-to-block functionality is enabled.

\requirement{CC:0062.04.04.11.01C}{0}

This field MUST be ignored by a node advertising no support for the block-to-block functionality in the Door Lock Capabilities Report Command.

\requirement{CC:0062.04.04.11.01D}{0}

The value 0 MUST indicate that the block-to-block functionality is disabled and the supporting node MAY ignore Door Lock Operation Set Commands if it detects to be already in the specified mode.

\requirement{CC:0062.04.04.11.01E}{0}

The value 1 MUST indicate that the block-to-block functionality is enabled and the supporting node MUST activate its motors until blocked to try to reach the mode indicated by Door Lock Operation Set Commands, even if it detects to be already in the specified mode.

2.2.40.7. Door Lock Configuration Get Command

This command is used to request the configuration parameters of a door lock device.

\requirement{CC:0062.04.05.11.001}{0}

The Door Lock Configuration Report Command MUST be returned in response to this command.

\requirement{CC:0062.04.05.51.001}{0}

This command MUST NOT be issued via multicast addressing.

\requirement{CC:0062.04.05.11.002}{0}

A receiving node MUST NOT return a response if this command is received via multicast addressing. The Z-Wave Multicast frame, the broadcast NodeID and the Multi Channel multi-End Point destination are all considered multicast addressing methods.

Table 2.215 Door Lock Configuration Get Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_CONFIGURATION_GET (0x05)

2.2.40.8. Door Lock Configuration Report Command

This command is used to advertise the configuration parameters of a door lock device.

Table 2.216 Door Lock Configuration Report Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_CONFIGURATION_REPORT (0x06)

Operation Type

Outside Door Handles Enabled

Inside Door Handles Enabled

Lock Timeout Minutes

Lock Timeout Seconds

Auto-relock time 1 (MSB)

Auto-relock time 2 (LSB)

Hold and release time 1 (MSB)

Hold and release time 2 (LSB)

Reserved

BTB

TA

Fields not described below MUST be according to descriptions in Section 2.2.40.6 Door Lock Configuration Set Command.

Outside Door Handles Enabled (4 bits)

This field is used advertise if each individual outside door handle is enabled at the supporting node. This field MUST be treated as a bitmask and MUST be encoded according to Table 2.209.

Inside Door Handles Enabled (4 bits)

This field is used advertise if each individual inside door handle is enabled at the supporting node. This field MUST be treated as a bitmask and MUST be encoded according to Table 2.209.

2.2.40.9. Door Lock Capabilities Get Command

This command is used to request the Door Lock capabilities of a supporting node.

\requirement{CC:0062.04.07.11.001}{0}

The Door Lock Capabilities Report Command MUST be returned in response to this command.

\requirement{CC:0062.04.07.51.001}{0}

This command MUST NOT be issued via multicast addressing.

\requirement{CC:0062.04.07.11.002}{0}

A receiving node MUST NOT return a response if this command is received via multicast addressing. The Z-Wave Multicast frame, the broadcast NodeID and the Multi Channel multi-End Point destination are all considered multicast addressing methods.

Table 2.217 Door Lock Capabilities Get Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_CAPABILITIES_GET (0x07)

2.2.40.10. Door Lock Capabilities Report Command

This command is used to advertise the Door Lock capabilities supported by the sending node.

Table 2.218 Door Lock Capabilities Report Command, version 4

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_DOOR_LOCK (0x62)

Command = DOOR_LOCK_CAPABILITIES_REPORT (0x08)

Reserved

Supported Operation type Bit Mask Length

Supported Operation Type Bit Mask 1

Supported Operation Type Bit Mask N

Supported Door Lock Mode List Length

Supported Door Lock Mode 1

Supported Door Lock Mode M

Supported Outside Handle Modes Bitmask

Supported Inside Handle Modes Bitmask

Supported door components

Reserved

ARS

HRS

TAS

BTBS

Reserved

\requirement{CC:0062.04.08.11.001}{0}

This field MUST be set to 0 by a sending node and MUST be ignored by a receiving node.

Supported Operation Type Bit Mask Length (5 bits)

This field is used to advertise the length in bytes of the Supported Operation Type Bit Mask field carried in the command.

\requirement{CC:0062.04.08.11.002}{0}

This field MUST be set to the minimum value which allows to advertise all supported Operation types.

Supported Operation Type Bit Mask (N bytes)

\requirement{CC:0062.04.08.11.003}{0}

This field is used to advertise the supported Door Lock Operation Types values. The length of this field in bytes MUST match the value advertised in the Supported Operation Type Bit Mask Length field.

\requirement{CC:0062.04.08.11.004}{0}

This field MUST be encoded as follows:

  • Bit 0 in Bit Mask 1 represents Operation Type 0x00 (Reserved)

  • Bit 1 in Bit Mask 1 represents Operation Type 0x01 (Constant operation)

  • Bit 2 in Bit Mask 1 represents Operation Type 0x02 (Timed operation)

Valid Operation Type values are defined in Table 2.214.

\requirement{CC:0062.04.08.11.005}{0}

If an Operation Type is supported, the corresponding bit MUST be set to ‘1’.

If an Operation Type is not supported, the corresponding bit MUST be set to ‘0’.

\requirement{CC:0062.04.08.11.006}{0}

All other bits are reserved and MUST be set to zero by a sending node. Reserved bits MUST be ignored by a receiving node.

\requirement{CC:0062.04.08.11.007}{0}

A node MUST support the constant operation type 0x01.

Supported Door Lock Mode List Length (8 bits)

\requirement{CC:0062.04.08.11.008}{0}

This field MUST advertise the length in bytes of the Supported Door Lock Mode field carried in the command.

Supported Door Lock Mode (M bytes)

\requirement{CC:0062.04.08.11.009}{4}

This field is used to advertise the supported Door Lock Modes values. The length of this field in bytes MUST match the value advertised in the Supported Door Lock Mode List Length field.

\requirement{CC:0062.04.08.11.00A}{0}

Each byte MUST indicate the value of a supported Door Lock Mode that can be specified in a Door Lock Operation Set Command. Each byte MUST be encoded according to Table 2.205.

\requirement{CC:0062.04.08.11.00B}{0}

A sending node MUST advertise support for the Door Lock modes 0x00 and 0xFF.

Supported Outside Handle Modes Bitmask (4 bits)

This field is used to advertise which outside handles can be enabled and disabled using the Door Lock Configuration Set Command.

\requirement{CC:0062.04.08.11.00C}{0}

This field MUST be treated as a bitmask and represent outside door handles as described in Table 2.209.

\requirement{CC:0062.04.08.11.00D}{0}

If the corresponding handle can be enabled and disabled, the corresponding bit MUST be set to 1.

If the corresponding handle cannot be enabled or disabled, the corresponding bit MUST be set to 0.

Supported Inside Handle Modes Bitmask (4 bits)

This field is used to advertise which inside handles can be enabled and disabled using the Door Lock Configuration Set Command.

\requirement{CC:0062.04.08.11.00E}{0}

This field MUST be treated as a bitmask and represent inside door handles as described in Table 2.209.

\requirement{CC:0062.04.08.11.00F}{0}

If the corresponding handle can be enabled, the corresponding bit MUST be set to 1.

If the corresponding handle cannot be enabled, the corresponding bit MUST be set to 0.

Supported Door components (8 bits)

\requirement{CC:0062.04.08.11.010}{0}

This field MUST advertise the supported door lock component that can be reported in the Door Lock condition field of the Door Lock Operation Report Command.

\requirement{CC:0062.04.08.11.011}{0}

This field MUST be treated as a bitmask and represent inside door handles as described in Table 2.219.

Table 2.219 Door Lock Capabilities Report::Supported Door components encoding

Bit 7..3

Bit 2

Bit 1

Bit 0

Reserved

Latch

Bolt

Door

\requirement{CC:0062.04.08.11.012}{0}

If the corresponding component is supported, the corresponding bit MUST be set to ‘1’.

If the corresponding component is not supported, the corresponding bit MUST be set to ‘0’.

ARS (Auto-Relock support) (1 bit)

This field is used to advertise if the sending node supports the auto-relock functionality.

\requirement{CC:0062.04.08.11.013}{0}

The value 1 MUST indicate that the auto-relock functionality is supported.

The value 0 MUST indicate that the auto-relock functionality is not supported.

HRS (Hold and release support) (1 bit)

\requirement{CC:0062.04.08.11.014}{0}

This field MUST advertise if the hold and release functionality is supported.

\requirement{CC:0062.04.08.11.015}{0}

The value 0 MUST indicate that the hold and release functionality is not supported

The value 1 MUST indicate that the hold and release functionality is supported.

TAS (Twist assist support) (1 bit)

\requirement{CC:0062.04.08.11.016}{0}

This field MUST advertise if the Twist Assist functionality is supported.

\requirement{CC:0062.04.08.11.017}{0}

The value 0 MUST indicate that the twist assist functionality is not supported

The value 1 MUST indicate that the twist assist functionality is supported.

BTBS (Block-to-block support) (1 bit)

This field is used to advertise if the block-to-block functionality is supported.

\requirement{CC:0062.04.08.11.018}{0}

The value 0 MUST indicate that the block-to-block functionality is not supported

The value 1 MUST indicate that the block-to-block functionality is supported.