2.2.50. Humidity Control Operating State Class, version 1

The Humidity Control Operating State Command Class is used to obtain the operating state of the humidity control device.

2.2.50.1. Humidity Control Operating State Get Command

This command is used to request the operating state of the humidity control device.

The Humidity Control Operating State Report Command MUST be returned in response to thiscommand.

This command MUST NOT be issued via multicast addressing.

A receiving node MUST NOT return a response if this command is received via multicast addressing. The Z-Wave Multicast frame, the broadcast NodeID and the Multi Channel multi-End Point destination are all considered multicast addressing methods.

Table 2.283 Humidity Control Operating State Get Command

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_HUMIDITY_CONTROL_OPERATING_STATE (0x6E)

Command = HUMIDITY_CONTROL_OPERATING_STATE_GET (0x01)

2.2.50.2. Humidity Control Operating State Report Command

This command is used to report the operating state of the humidity control device.

Table 2.284 Humidity Control Operating State Report Command

7

6

5

4

3

2

1

0

Command Class = COMMAND_CLASS_HUMIDITY_CONTROL_OPERATING_STATE (0x6E)

Command = HUMIDITY_CONTROL_OPERATING_STATE_REPORT (0x02)

Reserved

Operating State

Reserved

The reserved field is for future use. Reserved bits MUST be set to zero by a sending node. Reserved bits MUST be ignored by a receiving node.

Operating State (4 bits)

The Operating State field MUST advertise the current operating state.

The encoding of the Operating State field MUST be according to Table 2.285.

Table 2.285 Operating State

Operating State

Description

Version

0

Idle

1

1

Humidifying

1

2

De-humidifying

1

All other values are reserved. Reserved values MUST NOT be used by a sending node and MUST be ignored by a receiving node.